Faster Thickness Results
Streamline your ultrasonic thickness inspection process with one fast, connected, and reliable handheld gauge. The 39DL PLUS™ gauge works as a precision or corrosion thickness gauge for demanding applications.
With world-class ultrasonic capability, fast scanning speeds up to a 60 Hz update rate, and fully integrated wireless connectivity, our flagship handheld thickness gauge delivers results you can trust in a seamless workflow.
- Connected: Integrated Wi-Fi®, Bluetooth®, USB, RS-232, and a removable microSD card
- Fast: Scan for minimal thickness areas at a 2 times faster display update rate (Up to 60 Hz versus 30 Hz on the predecessor model and comparable handheld thickness gauges)
- Versatile: Tackle multiple thickness applications with our full line of dual and single element transducers
Affordable Part Scanning
With breakthrough scanning speeds, the 39DL PLUS instrument offers an industry-leading 60 Hz update rate for handheld thickness gauges.
- Works as an affordable alternative for inspection codes that require a 60 Hz display update rate for scanning; get the scanning speed of a flaw detector with the ease of use of a thickness gauge
- Find thin spots more easily when scanning for minimal thickness areas on pipes and other assets affected by corrosion

One Thickness Gauge for Multiple Applications
- Wide thickness range: 0,08 mm (0.003 in.) to 635 mm (25 in.) depending on material and transducer selection
- Corrosion thickness gauging with dual element transducers
- High Resolution software option of 0.001 mm or 0.0001 in. with single element transducers from 2.25 MHz to 30 MHz
- THRU-COAT™ technology and echo-to-echo measurements to measure through painted and coated surfaces
- Internal Oxide/Scale software option for boiler tube and internal oxide measurements
- Multilayer software option to measure up to four layers simultaneously
- High Penetration software option for attenuating materials such as fiberglass, rubber, and thick castings
- Standard resolution: 0.01 mm or 0.001 in. for all transducers
- Thickness, velocity, and time-of-flight measurements
- Differential mode and reduction rate mode to track thickness variation and its percentage from a preset value
- Time-based B-scan mode: 10,000 reviewable readings per scan
- High Dynamic Gain technology with digital filters optimizes the starting gain setting based on calibration
- V-Path Builder for custom V-path compensation in corrosion applications
- Designed for EN15317 compliance
- Compatible with all probes and accessories supported on the predecessor model
39DL PLUS™ Specifications
Measurements | Dual element transducer measurement mode | Time interval from a precision delay after the excitation pulse to the first echo |
THRU-COAT™ measurement | Measurement of true metal and coating thicknesses with a single back-wall echo (with D7906-SM and D7908 transducers) | |
Thru-Paint Echo-to-Echo | Time interval between two successive back-wall echoes to eliminate paint or coating thickness | |
Single element transducer measurement modes | Mode 1: Time interval between the excitation pulse and the first back-wall echo Mode 2: Time interval between the delay line echo and the first back-wall echo (with delay or immersion transducers) Mode 3: Time interval between successive back-wall echoes following the first interface echo after the excitation pulse (with delay line or immersion transducers) Oxide: optional Multilayer mode: optional | |
Thickness range | 0.08 mm to 635 mm depending on material, transducer surface conditions, temperature, and selected configuration | |
Material velocity range | 0.508 mm/μs to 13.998 mm/μs | |
Resolution (selectable) | Low: 0.1 mm | |
Standard: 0.01 mm | ||
High Resolution (optional): 0.001 mm | ||
Transducer frequency range | Standard: 2.0 MHz to 30 MHz (-3 dB) | |
High Penetration (optional): 0.50 MHz to 30 MHz (-3 dB) | ||
General | Operating temperature range | -10 °C to 50 °C |
Keypad | Sealed, color-coded keypad with tactile and audible feedback | |
Case | Impact-resistant and water-resistant, gasketed case with sealed connectors. Designed for IP67. | |
Dimensions (W x H x D) | Overall: 125 mm × 211 mm × 46 mm | |
Weight | 0,83 kg | |
Power supply | AC/DC adapter, 24 V; lithium-ion battery 23.760 Wh; or 4 AA auxiliary batteries | |
Battery life, lithium-ion | Operating time: typically 8 hours | |
Fast charge: 2 to 3 hours | ||
Standards | Designed for EN15317 | |
Explosive Atmosphere | Testing using MIL-STD-810H, Section 511.7, Procedure I | |
Display | Color transflective VGA display | Liquid crystal display, display area 56.16 mm x 74.88 mm |
Rectification | Full wave, RF, half-wave positive, or half-wave negative | |
Inputs/Outputs | USB | USB 3.0 |
RS-232 | Yes | |
Memory card | Maximum capacity: 32 GB external microSD memory card | |
Video output | VGA output standard | |
Wireless Communication | Wi-Fi® | Integrated |
Bluetooth® | Integrated | |
Internal Data logger | Data logger | The 39DL PLUS identifies, stores, recalls, clears, and transmits thickness readings, waveform images, and gauge configuration information through the standard RS-232 serial port or USB port |
Capacity | 792,832 thickness measurements or 20,000 waveforms with thickness measurements | |
File names, IDs, and comments | 32-character file names and 20-character alphanumeric location codes with four comments per location | |
File structures | Nine standard or custom application-specific file structures | |
Reports | On-gauge reporting of summary with statistics, Min./Max. with locations, Min. review, file comparison, and alarm report |
Standard Package*
39DL PLUS digital ultrasonic thickness gauge, AC or battery, 50 Hz to 60 Hz.
- Charger/AC adapter (100 VAC, 115 VAC, 230 VAC)
- Internal data logger
- GageView interface program
- Test block and couplant
- USB cable
- Rubber protective boot with gauge stand and neck strap
- User’s manual
- Measurement features: THRU-COAT, Thru-Paint Echo-to-Echo, EMAT compatibility, Min./Max. mode, two alarm modes, differential mode, B-scan, Application Auto-Recall, temperature compensation, Average/Min. mode
*The рackage can be changed according to the manufacturer’s decision. Please specify when ordering.
Software Options
- 39DLP-OXIDE (Q1470008): Code-activated Internal Oxide measurement software
- 39DLP-HR (Q1470006): Code-activated High Resolution measurement software
- 39DLP-MM (Q1470007): Code-activated Multilayer measurement software
- 39DLP-HP (Q1470005): Code-activated High Penetration (low frequency) measurement software
- 39DLP-EBSCAN (Q1470004): Encoded B-scan software
Optional Accessories
- 1/2XA/E110 (U8767104): Filter adapter for E110-SB EMAT transducer
- 38-9F6 (U8840167): RS-232 cable
- 38-C-USB-IP67 (U8800998): USB cable for IP67 sealed operation
- 38DLP/RFS (U8780288): Foot switch, factory installed
- HPV/C (U8780124): Digital caliper for thickness input for velocity measurements
- 38DLP-V-CC (U8840172): Cable for digital caliper
- EPLTC-C-VGA-6 (U8840035): VGA output cable
- MICROSD-ADP-2GB (U8779307): 2 GB external microSD memory card (gauge can use up to a 32 GB microSD card)
- BSCAN-ENC (U8779522): Encoded B-scan buggy
- 38DL-ENC-CBC-10 (U8840168): 10 ft encoder cable
- U8147016
- U8147014
- U8147015
- U8147017
- U8147018
- U8779306
- U8225961
- U8225960
- U8760054
- Q7790121
- U8778685
- U8767367
- U8780290
- U8780288
- U8778394
- U8778393
- U8800998
- U8764099
- U8840167
- U8778686
- Q2000755
- Q2000756
- Q2000757
- Q2000758
- Q2000759
- Q2000760
- Q2000761
- Q2000762
- Q2000763
- Q2000764
- Q2000765
- Q2000766
- Q1470008
- Q1470006
- Q1470007
- Q1470005
- Q1470004
- U8767104
- U8780124
- U8840172
- U8840035
- U8779307
- U8779522
- U8840168
- VIRTUAL - 38DLP MULTI-MEASURE SW
- VIRTUAL - 38DLP INTERNAL OXIDE SW
- VIRTUAL - 38DLP HIGH RESOLUTION SW
- VIRTUAL - 38DLP HIGH PENETRATION SW
- VIRTUAL - 38DLP ENCODED B-SCAN SW
- 38DLP/RPC RUBBER PROTECTIVE CASE
- 38DLP BASE KIT INTERNATIONAL KEYPAD
- 38DLP BASE KIT ENGLISH KEYPAD
- 38-BAT LI ION RECHARGEABLE BATTERY
- 10-007107-00
- 38DLP-EN-BASEKIT-FS
- 38DLP-ECA
- 38DLP-AA TRAY FOR AA BATT CELLS
- 38DLP/RFS Fact Inst Foot Switc
- 38DL PLUS REFERENCE CARD CZECH
- 38DL PLUS BASIC OP MANUAL CZECH
- 38-C-USB-IP67 SEALED USB CABLE
- 38-CC 38DL PLUS CARRYING CASE
- 38-9F6 RS-232 CABLE
- 38DLP-IN-BASEKIT-FS
- 39DLP/RFS-EN-BASEKIT-XX
- 39DLP/RFS-EN-BASEKIT-BX
- 39DLP/RFS-EN-BASEKIT-BW
- 39DLP/RFS-IN-BASEKIT-XX
- 39DLP/RFS-IN-BASEKIT-BX
- 39DLP/RFS-IN-BASEKIT-BW
- 39DLP-EN-BASEKIT-XX
- 39DLP-EN-BASEKIT-BX
- 39DLP-EN-BASEKIT-BW
- 39DLP-IN-BASEKIT-XX
- 39DLP-IN-BASEKIT-BX
- 39DLP-IN-BASEKIT-BW
- 39DLP-OXIDE
- 39DLP-HR
- 39DLP-MM
- 39DLP-HP
- 39DLP-EBSCAN
- 1/2XA/E110 FILTER ADAPT - E110 EMAT
- HPV/C DIG CALIPER 25HPV VT GAUGE
- 38DLP-V-CC DIG CALIPER CABLE
- EPLTC-C-VGA-6LF EP LTC VGA CABLE 6'
- MICROSD-ADP-2GB MICRO SD ADAPTOR
- BSCAN-ENC ENCODER BUGGY
- 38DLP-ENC-CBL-10 38DLP ENCODER CBL
Materials from the resource www.evidentscientific.com were used in the preparation of the website.
Need expert assistance?
We will select a solution after studying the technical conditions
Partnership
Active communication and consultations
We value feedback from our clients and actively consult with leading experts around the world to solve the most challenging NDT problems.